Mixing of metalworking fluids: water quality is a key factor To optimize the overall process safety and quality, a metalworking fluid emulsion must be perfectly balanced and stable. To accomplish that, it is crucial to maintain an ideal water quality. Unlike neat oils, which are used in metalworking operations in undiluted form, water-miscible fluids are normally diluted with water to form an emulsion. The concentrate consists of mineral oil or ester oil. Typically, the emulsion contains between 3 and 15% of concentrate. The main component of metalworking fluid emulsions is water. The quality of the water, which can vary widely by source, region and country, has a significant impact on the emulsion quality and its sump life. Therefore, it is inevitable to evaluate key characteristics such as water hardness and chloride concentration. The water quality (Video) Soft water increases foaming The water hardness determines the foam behaviour of many metalworking fluid emulsions. If the water is soft (below 8° dH/140 ppm), increased foaming may occur. If the water is very hard (well above 20° dH/350 ppm), it may have negative effects such as formation of lime (calcium) soaps, weakened corrosion protection, reduced emulsion stability and shorter sump life. The Blaser experts treat the water in various ways to achieve the ideal water hardness level for each process: If the water is too soft, calcium acetate can be added to increase the hardness. If it is too hard, the water can be treated by ion exchange to make it softer. Other water treatment procedures like reversed osmosis (RO) or de-ionization (DI) remove all salts. Water quality is key High chloride leads to corrosion Initial filling of machine Another important quality parameter is the chloride concentration in the water. Chloride should not exceed 25 mg/l, as it accumulates in the coolant over time. High chloride concentration may lead to corrosion on machines and work pieces, negatively influencing the process safety and efficiency. If the chloride concentration is too high, the water can be treated with the RO/DI procedures to reduce or eliminate the chloride. In most cases, normal tap water can be used for the initial filling of the machine, while treated water is recommended for the preparation of the top-up emulsion. However, some metalworking fluids need soft or even RO/DI water for a good long-term stability. How to check the water quality Both the water hardness and the chloride concentration can...
Mixing of metalworking fluids: perfect concentration ensures stable emulsion No matter whether the emulsion is mixed manually or with automatic mixing equipment: Either way, a precise concentration is key for a stable emulsion and optimized lubrication An ideal water quality is a prerequisite for the mixing of metalworking fluids. Once the water quality is evaluated and – if necessary – improved, the mixing process can start. Determining the concentration The typical concentration lies between 3 and 15%. A lot of know-how and experience is needed to determine a recommended concentration as accurately as possible. In order to do just that, the Blaser experts evaluate all production processes, tools and materials in detail. It is important that the mixing process is performed in a correct way to ensure a stable emulsion with finely dispersed oil droplets. The mixing can either be done automatically or manually. Measuring the concentration (Video) Jetmix ensures best results The easiest and most precise option is the automatic mixing. By using automatic equipment such as the Blaser Swisslube Jetmix or Mini-Jetmix, the best results can be achieved. The automatic mixing equipment from Blaser maintains a constant concentration, and a specially shaped nozzle creates shockwaves that keep the emulsion droplets small to form a finely dispersed emulsion. It is important to ensure that the emulsion cannot enter the drinking water system – that can be guaranteed with the installation of a backflush valve. Jetmix for best results Refractometer in use Manual mixing: keep stirring! If the emulsion is mixed manually, it is crucial to always add the concentrate to the water while stirring. The concentration must be checked with a refractometer, which measures the content of a solution by the refraction of light. In fact, even if the emulsion is mixed automatically and the unit has preselected concentration scales, it is recommended to double-check the concentration with a refractometer. Please note that the product-specific refractometer factor must be taken into consideration. The real concentration can be calculated by multiplying the refractometer reading in %brix with the refractometer factor. The refractometer factor of each coolant can be found on the product-specific data sheets. Once the concentration is ideal, the emulsion can be used for the production processes. Only a perfect concentration ensures that the emulsion remains stable and provides optimized...
What to do with your metalworking fluid during longer production stops? The machines may not be running, but chemistry and microbiology continue to be active in your water-miscible metalworking fluid. The fluid doesn’t circulate anymore and there’s no supply with fresh emulsion. All this can lead to severe problems such as bad smell, corrosion of machine parts and splitting of the emulsion. You therefore need to decide whether you maintain your coolant during the production stop or whether it’s a good opportunity to dispose your old coolant, clean your machines and get them ready for future production. Two options – maintain or dispose Water-miscible metalworking fluids cannot be left on their own. They need to be monitored and maintained regularly to ensure the stability of the emulsion. Cutting and grinding oils do not need any specific precautions. However, the production stop may be a good opportunity to clean the machines and change to a new oil. The following points help you decide whether to keep or dispose your metalworking fluid: Current conditions of the fluid Age of the fluid Volume of the fluid Expected duration of the production stop Available employees Please contact your Blaser representative to discuss which option is best for you. Equipment and methods in our microbiology laboratory It is crucial that you check and maintain the vital parameters of your coolant during production stops. For detailed instructions, see download section below or our online video tutorials. The most important measures are: Concentration: Keep at minimum 8%. This will ensure sufficient pH buffer to keep the emulsion stable. pH value: Make sure it remains within the recommended range. Circulation: Let the emulsion circulate in the tank for minimum 30 minutes per day. Skimmer: Keep it running. If you don’t have a skimmer, periodically remove tramp oil manually. Chip conveyor: Run it daily before starting the circulation. This will remove the chips and microchips that settle at the bottom of the tank. Machine cleaning – water-miscible metalworking fluids If you decide that the production stop is a good opportunity to dispose the old coolant, then proper cleaning of your machines is crucial to avoid contamination of the fresh emulsion. Watch the video for step-by-step instructions for cleaning and re-filling your machines. In the download section below, you can also find a PDF with all steps explained in detail. Machine cleaning – neat oils Although cutting and...
DNA and flow cytometry in the microbiology laboratory – CSI from Hasle-Rüegsau Microscope The world of bacteria and fungi is extremely varied. In order to understand these organisms, in addition to specialist knowledge and an instinct for investigative research, we need the right instruments in our laboratory. We need effective equipment and closely tailored analysis methods to provide our customers with even faster and more competent information about the used emulsion. Find out more about DNA analysis, flow cytometry and microscopy. In my last post “What happens to the cutting and grinding fluid samples”, I introduced you to our standard analysis methods (plater & dipslide). These methods offer an overview of which microorganisms are capable of growing on a given nutrient medium. But the ability to grow is just one of many aspects in obtaining information about the (microbiological) condition of a cutting and grinding fluid. The analysis methods Unfortunately, there is still no way to determine precisely the number of existing microorganisms or their type and activity in a short space of time. However, there are methods that enable us to speed up certain analyses and obtain more information. For example flow cytometry. A specially developed measuring method means we can now deliver the cutting and grinding fluid analysis to our customers within a few hours instead of two days. This improvement saves time and money. Equipment and methods in our microbiology laboratory Flow cytometry A flow cytometer enables microorganisms to be fed through a narrow measuring chamber at high speed and measured with the help of several lasers. The cells generate a scattered light which is measured by sensors. The processed data allows us to gain a comprehensive picture of the sample and the microorganisms present. In addition, the cells to be measured can be stained with fluorescent dyes to show the structures or life processes (e.g. activity). The great advantage of this method is the speed at which analysis can take place. Instead of requiring an incubation period of two days, evaluation with flow cytometry can be carried out within a few hours. This speeds up the customer’s reaction time enormously. Every organism stores its genetic information in a molecule known as DNA (DeoxyriboNucleic Acid). This stores the information that a cell needs to master all life processes. This stored information differs from organism to organism and thus enables classification...
Cutting and grinding fluid tests – performance comparisons among cutting and grinding fluids Precise analysis using the microscope in the Blaser Swisslube Technology Center My series explains which factors should be given special consideration when comparing cutting and grinding fluids. Having considered tool preparation and the right choice when replacing cutting and grinding fluids in the first two parts, the last part is about measuring performance and comparing different cutting and grinding fluids. What is particularly important when comparing sump life? All other factors, in addition to the cutting and grinding fluid, must be defined as precisely as possible. Good preparation is essential for reliable results and meaningful comparisons. In parts one and two, I already listed many factors that must be taken into account for a meaningful comparison of cutting and grinding fluids. I now intend to explain the procedure of our experiments in more detail in this part. Procedure of the performance test After the tools and cutting and grinding fluid have been prepared and checked, the performance test can begin. We machine material in our in-house Technology Center under clearly defined parameters until we have reached a predetermined flank wear, which marks the end of the sump life. We interrupt the machining process at fixed intervals, documenting the increase in tool wear using a microscope. It is essential that the machining conditions are always as identical as possible. The procedure of a cutting and grinding fluid test in the Blaser Technology Center To ensure reliable results, it is also important that the machining conditions are as good as possible. The main focus here is on clamping the workpiece, the tool and the machining strategy. Another essential factor is the pressure or the volume flow of the cutting and grinding fluid, which must be checked in advance to ensure consistency. Once all of these points have been checked, the test can begin. What must always be taken into account when performing cutting and grinding fluid tests in metalworking companies? 1. Process analysis: The real difference between cutting and grinding fluids can only be reliably shown through a structured approach and the prior identification of possible influencing factors. Even the most minor differences in material quality or tools can seriously falsify a comparison. 2. Process selection: Make sure to choose a stable process for comparison purposes. Otherwise, the...
Cutting and grinding fluid tests – what needs to be considered in cutting and grinding fluid management? Blaser Swisslube’s experts are bringing efficient coolants to market. But not before the products are subjected to in-depth performance tests at the Blaser Swisslube Technology Center. The testing equipment now includes a microscope camera for measuring tool wear and the spike sensor system from pro-micron for measuring cutting force. This allows for faster collection of meaningful data that is of benefit to the user. You need to proceed with care when comparing cutting and grinding fluids with one another. In the first part I explained the points to be noted with materials and tools. We now turn our attention to the cutting and grinding fluid and its handling. The cleaning of the machine—before filling—is the key to the successful use of the cutting and grinding fluid. You’ll find plenty of information and tips on handling our cooling lubricants in our application videos. Blaser’s Competence Center Professional machine cleaning demonstration After the machine has been thoroughly cleaned, two factors are particularly important for subsequent filling (with water-miscible cutting and grinding fluid): The cutting and grinding fluid concentration Water quality The cutting and grinding fluid concentration The concentration with which the cutting and grinding fluid is applied influences both the performance and the stability of the emulsion. The refractometer factor must be taken into account when checking the concentration with the refractometer. This is always shown on the product label of our products. This factor is multiplied by the refractometer reading and gives the effective concentration of the cutting and grinding fluid. Checking concentration using a refractometer The influence of the refractometer factor. Example with factors 1.0 and 1.5. We always work with the same concentration during our machining tests in the Technology Center. For general machining, this is 8 percent. By contrast, the tests for grinding are run with a concentration of 4 percent. Please note the application limits on the data sheet of the respective product. The concentration is checked daily during the experiments. In order to ensure the reproducibility of the test results, the deviation from the target concentration must not exceed a maximum of 0.5% during the entire test period. Furthermore, the total amount of cutting and grinding fluid must not fluctuate excessively...
We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. By clicking “Accept”, you consent to the use of ALL the cookies. Do not sell my personal information.
This website uses cookies to improve your experience while you navigate through the website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may affect your browsing experience.
Necessary cookies are absolutely essential for the website to function properly. These cookies ensure basic functionalities and security features of the website, anonymously.
Cookie
Duration
Description
_wpfuuid
1 year 1 month 4 days
This cookie is used by the WPForms WordPress plugin. The cookie is used to allows the paid version of the plugin to connect entries by the same user and is used for some additional features like the Form Abandonment addon.
cookielawinfo-checkbox-advertisement
1 year
Set by the GDPR Cookie Consent plugin, this cookie records the user consent for the cookies in the "Advertisement" category.
cookielawinfo-checkbox-analytics
1 year
Set by the GDPR Cookie Consent plugin, this cookie records the user consent for the cookies in the "Analytics" category.
cookielawinfo-checkbox-functional
1 year
The GDPR Cookie Consent plugin sets the cookie to record the user consent for the cookies in the category "Functional".
cookielawinfo-checkbox-necessary
1 year
Set by the GDPR Cookie Consent plugin, this cookie records the user consent for the cookies in the "Necessary" category.
cookielawinfo-checkbox-others
1 year
Set by the GDPR Cookie Consent plugin, this cookie stores user consent for cookies in the category "Others".
cookielawinfo-checkbox-performance
1 year
Set by the GDPR Cookie Consent plugin, this cookie stores the user consent for cookies in the category "Performance".
cookielawinfo-checkbox-strictly-necessary
1 year
Set by the GDPR Cookie Consent plugin, this cookie records the user consent for the cookies in the "Strictly Necessary" category.
CookieLawInfoConsent
1 year
CookieYes sets this cookie to record the default button state of the corresponding category and the status of CCPA. It works only in coordination with the primary cookie.
PHPSESSID
session
This cookie is native to PHP applications. The cookie stores and identifies a user's unique session ID to manage user sessions on the website. The cookie is a session cookie and will be deleted when all the browser windows are closed.
viewed_cookie_policy
1 year
The GDPR Cookie Consent plugin sets the cookie to store whether or not the user has consented to use cookies. It does not store any personal data.
This section is absolutely necessary for the site to function. There is no personal identifying information being collected or stored. However, there is a cookie that allows the functionality.
Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics the number of visitors, bounce rate, traffic source, etc.
Cookie
Duration
Description
_ga
1 year 1 month 4 days
Google Analytics sets this cookie to calculate visitor, session and campaign data and track site usage for the site's analytics report. The cookie stores information anonymously and assigns a randomly generated number to recognise unique visitors.
_ga_*
1 year 1 month 4 days
Google Analytics sets this cookie to store and count page views.
AnalyticsSyncHistory
1 month
Linkedin set this cookie to store information about the time a sync took place with the lms_analytics cookie.
Functional cookies help to perform certain functionalities like sharing the content of the website on social media platforms, collect feedbacks, and other third-party features.
Cookie
Duration
Description
geot_rocket_city
session
This cookie saves the access city information.
geot_rocket_country
session
This cookie saves the access country information.
geot_rocket_state
session
This cookie saves the access state information.
li_gc
6 months
Linkedin set this cookie for storing visitor's consent regarding using cookies for non-essential purposes.
lidc
1 day
LinkedIn sets the lidc cookie to facilitate data center selection.
STYXKEY_geot_country
session
This cookie allows the user to switch between country sites.
UserMatchHistory
1 month
LinkedIn sets this cookie for LinkedIn Ads ID syncing.
Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.
Advertisement cookies are used to provide visitors with relevant ads and marketing campaigns. These cookies track visitors across websites and collect information to provide customized ads.
Cookie
Duration
Description
bcookie
1 year
LinkedIn sets this cookie from LinkedIn share buttons and ad tags to recognize browser IDs.
bscookie
1 year
LinkedIn sets this cookie to store performed actions on the website.
li_sugr
3 months
LinkedIn sets this cookie to collect user behaviour data to optimise the website and make advertisements on the website more relevant.
Recent Comments